Product Details:
WavelengthsRed: 663 nanometers , Infrared: 890 nanometer
Device SizeDimensions: 274 mm x 184 mm x 115 mm
Water capacity:: To maximum fill line 360 mL
Sound Pressure Level< 28 dB, when the device is working at the pressure of 10 hPa
Weight:1.9 kg
Heated HumidifierHumidifier Settings: off, 1 to 5 (95F to 154.4F / 35C to 68C)
Pulse RateRange: 30 to 240 BPM , Margin of Error: +-2%
SpO2Range: 35% to 100%, The margin of error for SpO2 between 70% and 100% is +- 3%. No strict accuracy
TubeLength: 6 ft. (1.83 m)
Work ModeAuto CPAP, CPAP
Type of Protection Against Electric ShockClass II Equipment
Sound Power Level< 38 dB, when the device is working at the pressure of 10 hPa
Pressure :Range: 0 to 20 hPa , Margin of Error: +- (0.4 hPa + 4%)
Degree of Protection Against Electric ShockType BF Applied Part
Static Pressure Stability+-0.5 hPa
Automatic leak compensationThe pressure error <= +- 1 hPa when the air leakage is no more than 70 L/min.
Degree of Protection Against Ingress of WaterIP22
Ramp :The ramp time ranges from 0 to 60 minutes
Maximum FlowTest Pressures (hPa): 4, 10, 15, 20
Average Flow at the Patient Connection Port (L/min)85, 135, 140, 140
Maximal Optical Output PowerLess than 1.5 mw maximum average.
The Form and the Dimensions of the Patient Connection PortThe 22 mm conical air outlet complies with ISO 5356-1.
Product UseOperation Temperature: 5C to 35C (41F to 95F), Humidity: 15% to 93% Non-condensing
Humidifier Output:No less than 10 mg H2O/L
AC Power Consumption100 - 240 V AC, 50/60 Hz, 2.0 A
Measured Pressure at the Patient Connection Port (hPa)3, 9, 14, 19
Environmental Conditions:: Maximum airflow, 35C, 15% relative humidity
Mode of OperationContinuous
Pressure Range :4 to 20 hPa (in 0.5 hPa increments), <=30 hPa under single fault conditions.
Maximum Delivered Gas Temperature<= 43C
Transport and Storage-25C to 70C (-13F to 158F), 15% to 93% Non-condensing, 760 to 1060 hPa
SD CardThe SD card can record patient data and fault information

The RESmart G2S A20 is an auto-adjusting pressure CPAP (Continuous Positive Airway Pressure) device with integrated humidifier, designed for the treatment of adult Obstructive Sleep Apnea (OSA), either in the hospital or at home. With its affable appearance, stable performance, excellent comfort features, let you and your family say goodbye to snoring trouble and enjoy the whole night's sleep. 
Yes! I am Interested
Get CALLBACK

Icu Ventilator for Adult and Ped

Icu Ventilator for Adult and Ped
  • +2
 
Get Best Quote
Approx. Rs 5.75 Lakh / Piece
Get Latest Price
Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Invasive Ventilation Mode:VCV, PCV, VSIMV,PSIMV,CPAP/PSV,PRVC, V + SIMV, BPAP, APRV
Temperature:5-40 C (operating); -20 to 60C
Weight:(with trolley)Approximately 31.0 kg (with trolley)
Display Size:12.1 Color active matrix TFT touch
Vtapnea:Adult: 100-2000 mL
Power Battery BackupExternal AC power supply Input voltage: 100-240 V Input frequency: 50/60 Hz Input current: 2.5 A Max
Dimensions:336 mm x 330 mm x 345 mm
Display Resolution (H) x (V):1280 x 800 pixels
Sigh Switch:On, Off
Tube Type:Type: ET Tube, Trach Tube, Disable STRC
Tube I.D.:Adult: 5.0 -12.0 mm (increments of 0.5 mm) / Pediatric: 2.5 - 8.0 mm (increments of 0.5 mm)
Weight:9.5 kg
Patient Type:Adult, Pediatric, Neonate

A compact turbine driven ventilator with multi-function, covers thenon-invasive and invasive ventilation, and is suitable for treatmentof most patient type. LYRA x1 is versatile throughout hospital andtransport. Comprehensive ventilating modes, including APRV, PRVC,NIV are available for all your demands and for all type of patients fromneonatal to adult.A collapsible high-resolution touch-screen display makes LYRA x1 mountedon a trolley your choice for ICU applications, as well as a high performanceventilator throughout hospital and transport.

Additional Information:
  • Delivery Time: 3-4 Days
Yes! I am Interested
Explore More Products
X
Find UsAkash Tripathi (Brand Manager) Pristyn Care
3rd & 4th Floor Capital Cityscape, Golf Course Extension Road, Sector 66, Gurugram - 122101, Haryana, India
SEND SMS
SEND E-MAIL
Share Us: