Minimum Order Quantity | 5 Piece |
Disposable/ Reusable | Disposable |
Type | Surgical Equipments |
Usage/Application | Orthopaedic surgery |
Material | Plastic |
Brand | Molnlycke |
Color | White |
CE Marking | With CE Marking |
Feature | Single-use handpiece and re-usable AC adapter |
I Deal In | New Only |
High speed flow rate: | 1000-1300mil/min (coaxial tip) |
Low speed flow rate | 700ml/min |
Tube Length | 3 meters |
Batteries: | 10.5V/AA Alkaline Batteries x7 cells. |
Low speed power rate: | 6.0V / 14.5W |
Type B applied part: | small cone tip (optional), coaxial canal tip (optional). |
Spray Type | Short fan spray tip with splash shield |
Pulse rate: | 1500-1700 cycle/min |
Adjustable spray speed: | High or Low |
Canal Size | Long femoral canal tip |
High speed power rate: | 10.5V / 25W |
Pressure: | <15 PSI |
A pulsed lavage system is a medical device used for wound management and cleaning. It is designed to assist healthcare professionals in effectively cleaning and irrigating wounds, particularly chronic and acute wounds. The system usually consists of the following components:
Control Unit: This is the main unit of the system that houses the controls, settings, and interface. Healthcare professionals use the control unit to adjust parameters such as pulsation frequency, pressure, and fluid delivery.
Handpiece: The handpiece is the handheld device that delivers the pulsed fluid stream to the wound. It might have a trigger or button that allows the healthcare professional to control the delivery of the solution.
Fluid Delivery System: The system requires a sterile fluid solution, often saline, which is delivered through the handpiece to the wound site. The fluid helps flush away debris, contaminants, and bacteria from the wound.
Nozzles: Different nozzle attachments can be used with the handpiece to tailor the irrigation to the specific needs of different wounds. Nozzles might vary in shape, size, and pressure to accommodate various wound types and sizes.
Suction System (Optional): Some advanced pulsed lavage systems include a suction component to simultaneously remove the dislodged debris and excess fluid from the wound, enhancing the cleaning process.
Adjustable Parameters: Healthcare professionals can often adjust parameters such as pulsation frequency and pressure to suit the wound type and patient's condition.
Safety Features: Depending on the model, safety features might include pressure limits, alarms, and safeguards to prevent excessive pressure or fluid use.
Disposable Components: Many pulsed lavage systems use disposable components like tubing and nozzles to prevent cross-contamination between patients and reduce the risk of infection.
Portability: Some systems are designed to be portable, allowing for easy movement within healthcare facilities.
Minimum Order Quantity | 1 Piece |
Weight | Generator: 13lbs (5.9kg) Cart: 37lbs (16.8 kg) Footswitch: 8lbs (3.6kg) |
Product Group | Generators & Accessories |
Subcategory | GEN11 Generator & Accessories |
Category | Energy Sealing and Dissecting |
Available Products | GEN11, CRT11, AGA11, FSW11, GEN11VK, GENWAR1, GENWAR2, HGA11 |
Output | HRMONIC Output: 150 VAC RMS maximum 35 watts continous, 30-80 kHz (55.5 kHz unless otherwise ENSEAL |
Output Pt.2 | ENSEAL Output: Bipolar no neutral electrode required, 100 VAC RMS maximum, 200 watts maximum, 300-49 |
Transport and storage conditions | Temp.: -35C- 54C Humidity: 10-95% non-condensing Atmospheric Pressure Range 700hPa-1060hPa |
Overall Dimentions | Generator: 35.0cm X 35.5cm X 13.6cm Cart: 18.88 (48.0cm) X 22.11 (56.2cm) X 37.53 (95.3cm) |
Product Category | Energy Sealing and Dissecting |
Compatible with | All HARMONIC(TM) and ENSEAL(TM) devices |
Surgical Approach | Both |
Class of protection again electric shock | Class 1 |
Ingress protection G11 enclosure ingress protection G11 Footswitch | IP21 and IP68 |
Product Code | GEN11 |
Main input | 100-240 V.50/60 Hz, 500 VA |
Ambient operating conditions | Temperature: 15C - 27C Humidity: 30%-75% non-condensing Atmospheric pressure range: 700hPa-1060hPa |
Description | Generator compatible with all HARMONIC(TM) and ENSEAL(TM) devices |
Main Fuses | T5AL 250 V (Time-delay, 5AMP, glass body, 5x20mm package size, quantity:2) |
Degree of protection against electric shock | Type CF applied part consisting of the harmonic or enseal instruments |
Minimum Order Quantity | 1 Piece |
Codes | ECS21B, ECS25B, ECS29B, ECS33B |
Description | Circular Stapler, XL Sealed |
Device Technology | Adjustable Staple Height |
Lumen Diameter | 21mm, 25mm, 29mm, 33mm |
Staple Rows | 2 |
Open Staple Leg Length | 5.2mm |
Closed Staple Height | 1.5mm-2.2mm |
Staple Technology | B-Form |
Minimum Order Quantity | 10 Piece |
Staple Size | 35 W |
Brand | ligaSkin |
Model Name/Number | ligaSkin |
No. of Pins | 35 |
Material | Stainless Steel |
Disposable | Yes |
Sterile | Yes |
Color | White |
Pack Size | 10 Pcs per box |
Box Contain | 10 Units / Box |
Usage/Application | Hospitals |
Item Code | LIGASKIN35W |
Delivery Time | 5-7 Days |
Minimum Order Quantity | 10 Piece |
Staple Size | 35 W |
Brand | LIGASKIN |
Model Name/Number | LIGASKIN |
No. of Pins | 35 |
Material | Stainless Steel |
Disposable | Yes |
Sterile | yes |
Color | White |
Usage/Application | Hospitals |
Box Contain | 10 Units / Box |
Pack Size | 10 Pcs per box |
Item Code | LIGASKIN35W |
Delivery Time | 5-7 Days |
Minimum Order Quantity | 2 Piece |
Brand | Reach |
Model Name/Number | RCL6038S, RLC6038L,RLC6048L, RLC8038L, RLC8048L |
Sterile | ETO |
Color | Blue and Green |
Staple Leg Lengths | 60mm/80mm |
Meterials | Plastic and Titanium Alloy |
Packaging Type | 6 Cartridges/Box |
Lengths | 6-10 Inch |
Usage/Application | SINGLE |
Minimum Order Quantity | 6 Piece |
Staple Leg Length | 60 mm |
Staple Size | 45mm/60mm |
Brand | Reach |
Disposable | Yes |
Sterile | ETO |
Maximum Firings | 12 |
Available sizes | Articulating ENDO III 60mm - Length 448mm, Articulating ENDO III 60mm - Length 348mm |
Color | WHITE, BLUE, GREEN |
No Of Rows | Three Rows |
Device Technology | Manual |
Catlogue No | ENDSRC6025R, END6035R, ENDO6048R |
Materials | Plastic and Titanium Alloy |
Packaging Type | 6 Pcs per Box |
Minimum Order Quantity | 5 Piece |
Disposable/ Reusable | Disposable |
Type | Surgical Equipments |
Usage/Application | Orthopaedic surgery |
Material | Plastic |
Brand | Molnlycke |
Color | White |
CE Marking | With CE Marking |
Feature | Single-use handpiece and re-usable AC adapter |
I Deal In | New Only |
High speed power rate: | 10.5V / 25W |
Type B applied part: | small cone tip (optional), coaxial canal tip (optional). |
Canal Size | Long femoral canal tip |
High speed flow rate: | 1000-1300mil/min (coaxial tip) |
Low speed flow rate | 700ml/min |
Adjustable spray speed | High or Low |
Pressure: | <15 PSI |
Spray Type | Short fan spray tip with splash shield |
Batteries: | 10.5V/AA Alkaline Batteries x7 cells |
Pulse rate: | 1500-1700 cycle/min |
Tube Length | 3 meters |
Low speed power rate: | 6.0V / 14.5W |
A pulsed lavage system is a medical device used for wound management and cleaning. It is designed to assist healthcare professionals in effectively cleaning and irrigating wounds, particularly chronic and acute wounds. The system usually consists of the following components:
Control Unit: This is the main unit of the system that houses the controls, settings, and interface. Healthcare professionals use the control unit to adjust parameters such as pulsation frequency, pressure, and fluid delivery.
Handpiece: The handpiece is the handheld device that delivers the pulsed fluid stream to the wound. It might have a trigger or button that allows the healthcare professional to control the delivery of the solution.
Fluid Delivery System: The system requires a sterile fluid solution, often saline, which is delivered through the handpiece to the wound site. The fluid helps flush away debris, contaminants, and bacteria from the wound.
Nozzles: Different nozzle attachments can be used with the handpiece to tailor the irrigation to the specific needs of different wounds. Nozzles might vary in shape, size, and pressure to accommodate various wound types and sizes.
Suction System (Optional): Some advanced pulsed lavage systems include a suction component to simultaneously remove the dislodged debris and excess fluid from the wound, enhancing the cleaning process.
Adjustable Parameters: Healthcare professionals can often adjust parameters such as pulsation frequency and pressure to suit the wound type and patient's condition.
Safety Features: Depending on the model, safety features might include pressure limits, alarms, and safeguards to prevent excessive pressure or fluid use.
Disposable Components: Many pulsed lavage systems use disposable components like tubing and nozzles to prevent cross-contamination between patients and reduce the risk of infection.
Portability: Some systems are designed to be portable, allowing for easy movement within healthcare facilities.
Minimum Order Quantity | 5 Piece |
Disposable/ Reusable | Disposable |
Type | Surgical Equipments |
Usage/Application | Orthopaedic surgery |
Material | Plastic |
Brand | Molnlycke |
Color | White |
CE Marking | With CE Marking |
Feature | Single-use handpiece and re-usable AC adapter |
I Deal In | New Only |
High speed power rate: | 10.5V / 25W |
Pressure: | <15 PSI |
Spray Type | Short fan spray tip with splash shield |
Canal Size | Long femoral canal tip |
High speed flow rate: | 1000-1300mil/min (coaxial tip) |
Low speed flow rate | 700ml/min |
Tube Length | 3 meters |
Type B applied part | small cone tip (optional), coaxial canal tip (optional) |
Batteries | 10.5V/AA Alkaline Batteries x7 cells |
Pulse rate: | 1500-1700 cycle/min |
Adjustable spray speed: | High or Low |
Low speed power rate: | 6.0V / 14.5W |
A pulsed lavage system is a medical device used for wound management and cleaning. It is designed to assist healthcare professionals in effectively cleaning and irrigating wounds, particularly chronic and acute wounds. The system usually consists of the following components:
Control Unit: This is the main unit of the system that houses the controls, settings, and interface. Healthcare professionals use the control unit to adjust parameters such as pulsation frequency, pressure, and fluid delivery.
Handpiece: The handpiece is the handheld device that delivers the pulsed fluid stream to the wound. It might have a trigger or button that allows the healthcare professional to control the delivery of the solution.
Fluid Delivery System: The system requires a sterile fluid solution, often saline, which is delivered through the handpiece to the wound site. The fluid helps flush away debris, contaminants, and bacteria from the wound.
Nozzles: Different nozzle attachments can be used with the handpiece to tailor the irrigation to the specific needs of different wounds. Nozzles might vary in shape, size, and pressure to accommodate various wound types and sizes.
Suction System (Optional): Some advanced pulsed lavage systems include a suction component to simultaneously remove the dislodged debris and excess fluid from the wound, enhancing the cleaning process.
Adjustable Parameters: Healthcare professionals can often adjust parameters such as pulsation frequency and pressure to suit the wound type and patient's condition.
Safety Features: Depending on the model, safety features might include pressure limits, alarms, and safeguards to prevent excessive pressure or fluid use.
Disposable Components: Many pulsed lavage systems use disposable components like tubing and nozzles to prevent cross-contamination between patients and reduce the risk of infection.
Portability: Some systems are designed to be portable, allowing for easy movement within healthcare facilities.
Minimum Order Quantity | 1 Piece |
Brand | ROUND REACH |
Material | Plastic & steel |
Quantity Unit | Piece |
Model Part Number | CSUS8000 |
Display Type | Touch |
Weight | 5kg |
Operating Frequency | 55.5khz |
Operating Mode | Max/Min/Advance |
The Sound Reach™ ultrasonic scalpel system platform takes a giant leap forward. The 8000 generator features a brand new distinctive design and unique features that transforms the way surgery is performed. With advanced features like
Features:
· Low Initial Investment
· Low Operating Cost
· No Counter in Transducer/Handpiece
· Detachable Cable from Transducer/Handpiece
· No Separate Transducer/Handpiece required for OPEN & LAPAROSCOPIC Shear/Probe.
· Low Price Shear/Probe.
· Shear/Probe Compatible with Existing Ethicon Harmonic Machine.
· Design and Technology from USA.
· User Friendly.
Advantages:
Dissection, cutting and coagulation in a single device.
Increase quickness and efficiency in surgery, minimizing the need to change instruments.
No electricity flow through patient or medical practitioners.
Provides safety during surgery.
Minimal thermal spread
Reduces damage to adjacent tissue and organs.
Reliable and secure vessel sealing across a wide range of vessels.
Reduce the number of surgical devices needed to achieve haemostasis.
One-handed activation and rotation
Make it easy to use for surgeons.
Same transducer for all shear sizes
Reduces costs.
Shears compatible with other platforms
Provides savings and creates more value.
Minimum Order Quantity | 1 Piece |
Patient Type: | Adult, Pediatric, Neonate |
Tube Type: | Type: ET Tube, Trach Tube, Disable STRC |
Dimensions: | 336 mm x 330 mm x 345 mm |
Weight: | 9.5 kg |
Sigh Switch: | On, Off |
Weight:(with trolley) | Approximately 31.0 kg (with trolley) |
Display Size: | 12.1 Color active matrix TFT touch |
Display Resolution (H) x (V): | 1280 x 800 pixels |
Tube I.D.: | Adult: 5.0 -12.0 mm (increments of 0.5 mm) / Pediatric: 2.5 - 8.0 mm (increments of 0.5 mm) |
Temperature: | 5-40 C (operating); -20 to 60C |
Invasive Ventilation Mode: | VCV, PCV, VSIMV,PSIMV,CPAP/PSV,PRVC, V + SIMV, BPAP, APRV |
Vtapnea: | Adult: 100-2000 mL |
Power Battery Backup | External AC power supply Input voltage: 100-240 V Input frequency: 50/60 Hz Input current: 2.5 A Max |
Minimum Order Quantity | 1 Piece |
Usage/Application | Hospital |
Brand | HARMONIC |
Pieces/Pack | Yes |
Is It Portable | Portable |
Compatible with | SNGCB, SNGHK, SNGHK2, HAR9F, HAR17F |
QTY/BX | 1 |
Warranty | 1 Year |
ISO Certified | Non Certified |
I Deal In | New and Second Hand |
Surgical Approach | Both |
Category | Energy Sealing and Dissecting |
Automation Grade | Manual |
Hand Piece compatible | with SNGCB, SNGHK, SNGHK2, HAR9F, HAR17F |
Color | Blue |
Speed | High Speed |
Subcategory | GEN11 Generator & Accessories |
Minimum Order Quantity | 2 Piece |
Brand | Ethicon |
Color | Blue, Yellow, Green |
Wire Diameter | .23mm |
Open Staple Height | 4.4mm |
Product codes | RELOADS - SR-55,75,mm - Universal And RELOADS - 100,55,75mm - Blue |
Reload Code | SR55, SR75 |
Tissue | Regular, Regular/Thick, Thick |
Selectable Closed Staple Height | 1.5mm, 1.8mm, 2.0mm |
Oxygen concentration | adjustable,Monitorable |
SmartFlow | Yes |
Pulse rate | Option |
Twin turbine motor | Yes |
Adjustment method of Oxygen concentration | Auto |
Flow Monitorable | adjustable Monitorable |
Temperature output range | 29C~37C |
Temperature adjustment gear | 9 steps adjustable |
sPEEP | Monitorable |
Disinfection-free conception | Yes |
Trend review function | 1 day; 3 days; 7 days |
Temperature: | Monitorable, adjustable |
SpO2 | Option |
Automatic water filling function | Yes |
Humidity compensation | -3~+3, 7 steps adjustable |
Warm standby | Yes |
sPEEP set | 0~4 adjustable |
Flow range | 2L-80L/min |
Oxygen concentration adjustment range | 21%-100% |
Screen size | 3.5 inches |
Automatic reminder of filter replacement | Yes, settable |
AutoFlow | Yes |
Minimum Order Quantity | 1 Piece |
Syringe Size | 2 ml,5 ml, 10 ml,20 ml,30 ml,50/60 ml |
Accuracy | +2% |
Dimension | 278x145x106mm (W x D x H); 1.5kg |
Alarm | Battery exhausted alarm, Low battery alarm,Near end alarm, VTBI finished alarm |
Flow Rate Accurancy | 2ml:0.1-100ml/h;5ml:0.1-150ml/h; 10ml:0.1-400ml/h;20ml:0.1-600ml/h; 30ml:0.1-800ml/h;50/60ml:0.1-180 |
Bolus Rate | 2 ml Syringe: 0.1-100 ml/h;5 ml Syringe: 0.1-150 ml/h; |
KVO Rate | Flow rate < 1ml/h: KVO rate = Flow rate |
KVO Rate | Flow rate >= 10ml/h: KVO rate 3 ml/h |
power: | A.C. 100 -240V 50/60Hz, Input D.C. 15V/2A Output, Input Voltage to Device |
KVO Rate | Flow rate >=1ml/h and <10ml/h: KVO rate 1 ml/h |
Occlusion Pressure | Two levels: High, Low H: 100 kpa; L: 50 kpa |
Volume Infused | 0.1~9999.9 ml, Step by 0.1 ml |
Bolus Rate: | 30 ml Syringe: 0.1-800 ml/h;50/60 ml Syringe: 0.1-1800 ml/h |
Bolus Rate: | 10 ml Syringe: 0.1-400 ml/h;20 ml Syringe:0.1- 600 ml/h; |
Classification | Class II, Type CF, IPX2 |
Power and Battery | 55VA Max; Battery Voltage 10.8V; Support 6 Hours normal operation |
Minimum Order Quantity | 1 Piece |
Brand | Genuine |
Model Name/Number | GXL HF 3.5kW/6 kW |
Clearance | 775 mm |
Lateral Movement | Steering Handle |
Locking Mechanism | Locks for all the manual Movement of C-Arm |
Axial Rotation | 180 Degrees |
Arc-Depth | 643 mm |
Source to Il distance | 950 mm |
Swivel Range | 12.5 Degrees |
Arc Orbital Movement | 125 Degrees |
Horizontal Movement | 200 mm |
Vertical Movement | 400 mm |
GXL HF 6 kW C-ARM | SPECIFICATION | GXL HF 3.5 kW C-ARM |
100 KHz High Frequency | Type of Generator | 100 KHz High Frequency |
230V, 50Hz, Single Phase, 15Amp + 10% | Power Requirement | 230V, 50Hz, Single Phase, 15Amp +10% |
Dual Focus Rotating Anode | Tube Type | Dual Focus Stationary Anode |
Small Focus : 0.3mm X 0.3mm Large Focus : 0.6mm X 0.6mm | Focal Spot | Small Focus : 0.6mm X 0.6mm Large Focus : 1.5mm X 1.5mm |
40 kVp to 120 kVp (in 80 Steps) | Fluoroscopic kVp | 40 kVp to 110 kVp (in 60 Steps) |
0.1 mA to 5.0mA | Normal Fluoroscopy | 0.1 mA to 3.5mA |
0.1 mA to 12.0 mA | HD Fluoroscopy | 0.1 mA to 8.0 mA |
5 Min. Cumulative (Temperature Controlled) | Fluoroscopic Timer | 5 Min. (Temperature Controlled) |
10" Touch Screen Control Panel | Control Panel | 10" Touch Screen Control Panel |
40 kVp to 120 kVp | Radiographic kVp | 40 kVp to 110 kVp |
0.1 to 200mAs | Radiographic mAs | 0.1 to 200 mAs |
An Inbuilt Rad Timer Enable To Show | An Inbuilt Rad Timer Enable To Show | |
Continuous Variable mAs For | Radiographic Timer | Continuous Variable mAs For |
Radiography | Radiography | |
Self Diagnostic Errors For Protections | Self Diagnostic | Self Diagnostic Errors For Protections |
ABS Control is Provided | Automatic Dose Rate | ABS Control is Provided |
9.3" Flat Panel Detector A-Si Active TFT Direct Deposit Csl | Flat Panel Detector | 9.3" Flat Panel Detector A-Si Active TFT Direct Deposit Csl |
32" Full HD LED Monitor | Monitor | 32" Full HD LED Monitor |
CPU Based Memory with Advance Post Processing Features | Memory | CPU Based Memory with Advance Post Processing Features |